I-PAC900S12-B2

I-AC kuya ku-DC Power Supply HVDC-DC Module

I-PAC900S12-B2 isekela okokufaka kwe-AC kuka-90 V kuya ku-264 V kanye nokokufaka kwe-HVDC kuka-180 V kuya ku-300V.
I-PSU inikeza okukhiphayo okukodwa futhi isekela izindlela ezintathu zokuphuma i-MV12, SV12 ne-MV6.


I-Linkedin
43f45020
384b0cad
754c4db4
6ec95a4a

Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Amandla okukhiphayo alinganiselwe ngu-900 W. I-PSU iyashintshashintsha, ilingana neyamanje, futhi isekela uxhumano oluhambisanayo olu-1+1 noma 2+2.
I-PSU isekela ukuxhumana kwe-PMBus, futhi ithumela ulwazi lwe-PSU ohlelweni ukuze kube lula ukuqapha nokuphatha.

Izici
● fficc 94% (Vin = 230 V AC, Pout = 450 W, TA =25°C, ngaphandle kwefeni)
● Ukujula x Ububanzi x Ubude: 183.0 mm x 68.0 mm x40.5 mm
● Igridi yamandla: 110 V AC/220 V AC isigaba esisodwa, 240 VDC
● Isekela ukuvikelwa kokokufaka kwe-AC kokungena kwamandla kagesi, i-overvoltage,
i-overcurrent, i-short circuit, kanye ne-PFC overvoltage
● Isekela ukuvikelwa kokokufaka kwe-HVDC ku-overvoltage, undervoltage, kanye ne-PFC overvoltage
● Isekela ukuvikelwa kokuphumayo kokugeleza kwe-overvoltage, i-overcurrent, i-short circuit, kanye nezinga lokushisa elingaphezulu
● I-I2C yokulawula, ukuhlela, nokuqapha
● Umbiko we-CE, UL, TUV, CCC, BSMI, BIS cfic kanye ne-CB uyatholakala
● 80 Plus amandla eplatinamu fficc cfic
● IEC 60950-1, EN 60950-1, UL 60950-1, GB 4943.1,IEC 62368-1
● Ithobelana ne-RoHS
Izicelo: Iseva
I-PSU ingakwazi ukumelana ne-voltage yokufaka engu-318 V AC amahora angu-48 (isimo esingasebenzi samukelekile).
I-inrush current kufanele ihlangabezane nezidingo ku-ETSI EN 300 132-3.
Lapho uhlola ubuningi bamanje bokufakwayo, qinisekisa ukuthi i-voltage yembobo yokufaka amandla ihlangabezana nemfuneko nokuthi okukhiphayo kungu-900 W.
Izidingo Zamanje Zomklamo Wokwabelana
1. Isekela imodi engu-1+1 noma engu-2+2.Ukwabelana kwamanje kuphela kumodi ye-MV12.
2. Isamba somthwalo ekuqaliseni kuzimo zokusebenza okufanayo kufanele sibe ngaphansi komthwalo olinganiselwe we-PSU eyodwa.
3. Uma ama-PSU asebenza kumodi engu-1+1 noma engu-2+2, uma enye ye-PSU isebenza kumodi ye-MV6 kanti amanye ama-PSU asebenza kumodi ye-MV12, ama-PSU kufanele asebenze kahle ngaphandle kwe-ffc yodwa.
4. Ezimeni lapho ama-ff PSUs engafakiwe ndawonye, ​​amasiginali e-I-MON yama-PSU amabili akufanele asuse ukusebenza okuvamile kwama-PSU lapho exhumeke ngokuqondile.
5. Ukungalingani kokwabelana kwamanje kuphela esimweni sokushisa esivamile.